Elifast implant

ElifastSpiral

Elifast Implant is the evolution of the Implant System more utilized in the field of Dentistry Implantology.
Elifast Implant System is in compliance with all the Quality Biomedical Sector Standards.

Elifast Implant System exceed the highest standards set by the European Community and other international agencies starting from the use of the materials until to surface- decontamination and sterilization treatments .

The double thread reduces the time necessary for the insertion of the implant

Made of pure titanium in compliance with the standard ASTM F67 grade 4

 

 

Fastite acid etch

insertgrip-3

The innovative Fastite surface is realized with a double passage of acid etch treatment, a passage of passivation and a final treatment of Ar-plasma decontamination. The procedures of grit blasting are not effected because they have shown evident limits as the contamination of the surface treated by the particles used during the procedure, which they are englobed, during the impact, in the same surface, creating non homogeneous surfaces that can weak the structure of the implant besides.
The Fastite surface, after a series of clinical multicentrices studies on 5.000 implants, have brought a percentage of very elevated success after 12 months from the prosthetic load, underlining the possibility to load the implants after 60 days from their insertion.


The Fastite acid etched surface appeared to provide stronger anchoring in the bone and also offering important clinical advantages in bone of low quality because favours the formation of compact bone along the central coils and in the apical zone of the implant.

 

Diameters and lenghts

Diameter (mm)
3,75 4,25 5,00
8,50 8,50 8,50
10,00 10,00 10,00
12,00 12,00 12,00 
14,00 14,00 14,00 
16,00 16,00  
Lenghts (mm)

 

 

Elifast instructions for use

final package3 F INSTR 1 F INSTR 2
 External box: the implant is in a glass phial externally packaged. The red circular label identifies gamma irradiation sterilized condition. The box includes two adhesive labels with implant data and the use instructions. Open the package and take the glass phial. Unscrew the cap. You find the Elifast implant inserted on the titanium cylinder with his implant mount premounted on the platform of the implant  Capture the Elifast implant with the Friction Hand Wrench (Cod. CHV777-1) or with the motor adaptor short or long (Cod. DDM01-DDM02). 
F INSTR 3  F INSTR 4  
 

After the surgical insertion of the Elifast implant extract the titanium cylinder from the glass phial.
The cover screw is screwed on the bottom side of the titanium cylinder.

Unscrew the cover screw with the Long Handle Driver or with the Contra Angle Driver short or long (cod. DVR888 or cod. CDM01-CDM02).

 
Screw the cover screw on the platform of the Elifast implant ending the surgical site by suture.

 

Elifast radiographic transparencies

RAD ELIFAST 1-125i

 

Elifast codes

 

ELIFAST 3,75
 
 
 
EF108
ELIFAST IMPLANT DIAMETER 3,75 X 8,5 mm.
EF110
ELIFAST IMPLANT DIAMETER 3,75 X 10 mm.
EF112
ELIFAST IMPLANT DIAMETER 3,75 X 12 mm.
EF114
ELIFAST IMPLANT DIAMETER 3,75 X 14 mm.
EF116
ELIFAST IMPLANT DIAMETER 3,75 X 16 mm.
ELIFAST 4,25
EF408
ELIFAST IMPLANT DIAMETER 4,25 X 8,5mm.
EF410
ELIFAST IMPLANT DIAMETER 4,25 X 10 mm.
EF412
ELIFAST IMPLANT DIAMETER 4,25 X 12 mm.
EF414
ELIFAST IMPLANT DIAMETER 4,25 X 14 mm.
EF416
ELIFAST IMPLANT DIAMETER 4,25 X 16 mm.
ELIFAST 5,00
EF508
ELIFAST IMPLANT DIAMETER 5,00 X 8,5 mm.
EF510
ELIFAST IMPLANT DIAMETER 5,00 X 10 mm.
EF512
ELIFAST IMPLANT DIAMETER 5,00 X 12 mm.
EF514
ELIFAST IMPLANT DIAMETER 5,00 X 14 mm.